Sea-Bird Electronics, Inc. 13431 NE 20th StreetBellevue, Washington 98005 USA Tel: 425/643-9866 Fax:425/643-9954 SBE 45 MicroTSGTHERMOSALINOGRAP
2 Limited Liability Statement Extreme care should be exercised when using or servicing this equipment. It should be used or serviced only by personn
WARRANTY POLICY 2010 PRODUCT WARRANTY 5-YEAR LIMITED WARRANTY (NEW PRODUCTS) For a period of five years after the date of original shipment from
WARRANTY ADMINISTRATION POLICY Sea-Bird Electronics, Inc. and its authorized representatives or resellers provide warranty support only to the orig
SOFTWARE WARRANTY SOFTWARE LICENSE AGREEMENT By downloading or installing any of our software, you expressly agree to the following: Sea-Bird&apo
Sea-Bird Service Request Form To return instruments for calibration or other service, please provide the information below, so we can serve you bette
PAYMENT/BILLING INFORMATION [ ] Credit Card (Sea-Bird accepts payment by VISA, Master Card, or American Express) Name on Card: Please call Ch
Table of Contents SBE 45 3Table of Contents Section 1: Introduction ... 5 Ab
Table of Contents SBE 45 4Appendix I: Functional Description... 43 Sensors...
Section 1: Introduction SBE 45 5Section 1: Introduction This section includes a Quick Start procedure, and photos of a standard SBE 45 MicroTSG
Section 1: Introduction SBE 45 6Unpacking MicroTSG Shown below is a typical MicroTSG shipment.
Section 2: Description of MicroTSG SBE 45 7Section 2: Description of MicroTSG This section describes the functions and features of the MicroTSG,
Section 2: Description of MicroTSG SBE 45 8An optional AC- or DC-powered 90402 - SBE 45 Power, Navigation, and Remote Temperature Interface Box pr
Section 2: Description of MicroTSG SBE 45 9Specifications Temperature (°C) 1 Conductivity (S/m) Salinity (PSU), typical Measurement Range -5
Section 2: Description of MicroTSG SBE 45 10Dimensions and Connector Dimensions in millimeters (inches) Ground pin = Computer data
Section 2: Description of MicroTSG SBE 45 11Sample Timing The time to acquire the temperature and conductivity varies, depending on the mode of o
This page intentionally left blank.
Section 2: Description of MicroTSG SBE 45 12Baud Rate, Cable Length, Power, and Data Transmission Rate Baud Rate, Cable Length, and Data Transmi
Section 2: Description of MicroTSG SBE 45 13Power and Cable Length There are two issues to consider: • Limiting the IR loss to 1 volt; higher I
Section 2: Description of MicroTSG SBE 45 14Remote Temperature Sensor (optional) The optional 90402 – SBE 45 Power, Navigation, and Remote Tempe
Section 3: Installing System SBE 45 15Section 3: Installing System This section provides information on: • Software installation • System schem
Section 3: Installing System SBE 45 16System Schematic and Installation Guidelines MicroTSG with Optional PN 90402 Interface Box, SBE 38 Remot
Section 3: Installing System SBE 45 17Sea-Bird does not provide detailed installation instructions for the MicroTSG, given the unique nature of ev
Section 3: Installing System SBE 45 18Power-Up Jumper Check The MicroTSG’s Printed Circuit Board (PCB) has a jumper that controls how the MicroT
Section 3: Installing System SBE 45 19Installing MicroTSG 1. New MicroTSGs are shipped with an AF24173 Anti-Foulant Device pre-installed. Verify
Section 4: Setting Up MicroTSG SBE 45 20Section 4: Setting Up MicroTSG This section provides information on: • MicroTSG setup • Sampling modes
Section 4: Setting Up MicroTSG SBE 45 21 2. The main screen looks like this: • Menus – Contains tasks and frequently executed instrument comma
SEA-BIRD ELECTRONICS, INC. 13431 NE 20th St.Bellevue, Washington 98005 USAPhone: (425) 643 9866Fax: (425) 643 9954Email: [email protected] 45 M
Section 4: Setting Up MicroTSG SBE 45 22Following are the Toolbar buttons applicable to the MicroTSG: Toolbar Buttons Description Equivalent Comm
Section 4: Setting Up MicroTSG SBE 45 23 4. In the Communications menu, select Options / Cycle baud when connecting. 5. Click Connect on the T
Section 4: Setting Up MicroTSG SBE 45 24Sampling Modes The MicroTSG has three basic sampling modes for obtaining data: Polled Sampling, Autonomou
Section 4: Setting Up MicroTSG SBE 45 25Autonomous Sampling The MicroTSG samples data at pre-programmed intervals, defined by Interval=, and send
Section 4: Setting Up MicroTSG SBE 45 26Serial Line Synchronization (Serial Line Sync) In Serial Line Sync Mode, a simple pulse (a single charact
Section 4: Setting Up MicroTSG SBE 45 27Command Descriptions This section describes commands and provides sample outputs. See Appendix III: Comma
Section 4: Setting Up MicroTSG SBE 45 28Setup Commands Baud=x x= baud rate (1200, 2400, 4800, 9600, 19200, or 38400). Default 4800. Outp
Section 4: Setting Up MicroTSG SBE 45 29Operating Commands Operating commands configure the MicroTSG’s response upon waking up, and direct the Mi
Section 4: Setting Up MicroTSG SBE 45 30Polled Sampling Commands These commands are used by an external controller to request a sample from the M
Section 4: Setting Up MicroTSG SBE 45 31Calibration Coefficients Command DC Display calibration coefficients. Equivalent to Coefficients on Tool
Manual Generation Date: 26 August 20111
Section 4: Setting Up MicroTSG SBE 45 32Data Output Format Each scan ends with a carriage return <CR> and line feed <LF>. Leading zer
Section 4: Setting Up MicroTSG SBE 45 33Setting Up Configuration (.xmlcon or .con) File Seasave and SBE Data Processing, our real-time data acqu
Section 5: Operating System SBE 45 34Section 5: Operating System This section covers acquiring real-time data with Seasave, and processing data w
Section 5: Operating System SBE 45 354. In the RealTime Data menu, select Start Acquisition. The dialog box looks like this: 5. In the Start R
Section 5: Operating System SBE 45 36Processing Data Process the data in SBE Data Processing. 1. Convert the .hex data file created by Seasave
Section 6: Routine Maintenance and Calibration SBE 45 37Section 6: Routine Maintenance and Calibration This section reviews corrosion precaution
Section 6: Routine Maintenance and Calibration SBE 45 38Step 3: Flush Inside of Conductivity Cell A. Remove the external plumbing connecting the
Section 6: Routine Maintenance and Calibration SBE 45 39Replacing Anti-Foulant Device (SBE 45) The MicroTSG has an anti-foulant device cup inside
Section 6: Routine Maintenance and Calibration SBE 45 40Sensor Calibration Sea-Bird sensors are calibrated by subjecting them to known physical c
Section 7: Troubleshooting SBE 45 41Section 7: Troubleshooting This section reviews common problems in operating the MicroTSG, and provides the m
L I M I T E D L I A B I L I T Y S T A T E M E N T Extreme care should be exercised when using or servicing this equipment. It should be used orse
Glossary SBE 45 42Glossary Fouling – Biological growth in the conductivity cell during deployment. PN 90402 - SBE 45 Power, Navigation, and Remote
Appendix I: Functional Description SBE 45 43Appendix I: Functional Description Sensors The MicroTSG embodies the same sensor elements (3-electro
Appendix II: Electronics Disassembly/Reassembly SBE 45 44Appendix II: Electronics Disassembly/Reassembly Do not disassemble the MicroTSG electro
Appendix III: Command Summary SBE 45 45Appendix III: Command Summary CATEGORY COMMAND DESCRIPTION Status DS Display status. Baud=x x= baud rate (
Appendix III: Command Summary SBE 45 46 CATEGORY COMMAND DESCRIPTION TS Take sample, hold converted data in RAM, output converted data TSR Take sa
Appendix IV: AF24173 Anti-Foulant Device SBE 45 47Appendix IV: AF24173 Anti-Foulant Device AF24173 Anti-Foulant Devices supplied for user replac
Appendix IV: AF24173 Anti-Foulant Device SBE 45 48AF24173 Anti-Foulant Device FOR USE ONLY IN SEA-BIRD ELECTRONICS’ CONDUCTIVITY SENSORS TO CONTR
Appendix IV: AF24173 Anti-Foulant Device SBE 45 49PRECAUTIONARY STATEMENTS HAZARD TO HUMANS AND DOMESTIC ANIMALS DANGER Corrosive - Causes irre
Appendix IV: AF24173 Anti-Foulant Device SBE 45 50 STORAGE AND DISPOSAL PESTICIDE STORAGE: Store in original container in a cool, dry place. Pre
Appendix V: Replacement Parts SBE 45 51Appendix V: Replacement Parts Part NumberPart Application Description Quantity in MicroTSG30541 3/8"
This page intentionally left blank.3
Index SBE 45 52Index . .con file · 33 .xmlcon file · 33 A Anti-Foulant Device · 47 removal before shipping to Sea-Bird · 40 replacing · 39 B Baud ra
Index SBE 45 53S Sample timing · 11 Sampling modes · 24 SBE 38 remote temperature sensor · 14, 16 SBE Data Processing · 8, 15, 33, 36 Schematic · 16
Reference Sheet Version #007, 06-11-08; Firmware Version 1.1b 1SBE 45 MicroTSG (RS-232) Reference Sheet (see SBE 45 MicroTSG User’s Manual for comple
Reference Sheet Version #007, 06-11-08; Firmware Version 1.1b 2Command Instructions and List • Input commands in upper or lower case letters and reg
MicroTSG (Thermosalinograph)SBE 45Sea-Bird Electronics, Inc.13431 NE 20th Street, Bellevue, Washington 98005 USAWebsite: http://www.seabird.comE-mai
MicroTSG (Thermosalinograph)SBE 45Sea-Bird Electronics, Inc.13431 NE 20th Street, Bellevue, Washington 98005 USAWebsite: http://www.seabird.comE-mai
CALIBRATION SHEETSSBE 45 Temperature Calibration - S/N 0383...
SEA-BIRD ELECTRONICS, INC.13431 NE 20th Street, Bellevue, Washington, 98005-2010 USAPhone: (425) 643 - 9866 Fax (425) 643 - 9954 Email: seabird@seabir
SEA-BIRD ELECTRONICS, INC.13431 NE 20th Street, Bellevue, Washington, 98005-2010 USAPhone: (425) 643 - 9866 Fax (425) 643 - 9954 Email: seabird@seabir
APPLICATION NOTESAppnote 2DConductivity...
1 APPLICATION NOTE NO. 2D Revised October 2010 Instructions for Care and Cleaning of Conductivity Cells This application note presents new re
2Rinsing, Cleaning, and Storage Procedures Note: See Cleaning Materials below for discussion of appropriate sources / concentrations of water, Trito
3Cleaning Materials Water De-ionized (DI) water, commercially distilled water, or fresh, clean, tap water is recommended for rinsing, cleaning, an
4Acid In rare instances, acid cleaning is required for mineral contamination of the conductivity cell. Sea-Bird recommends that you return the equip
5Application Note Revision History Date Description January 1998 Initial release. October 2002 Remove reference to part number for the small anti-
APPLICATION NOTE NO. 6 Revised August 2004 DETERMINATION OF SOUND VELOCITY FROM CTD DATA Use of CTD measurement for determination of sound vel
We draw the following conclusions from the research papers listed above: 1) Investigators using specialized equipment under scrupulously controlled
APPLICATION NOTE NO. 10 Revised March 2008 COMPRESSIBILITY COMPENSATION OF SEA-BIRD CONDUCTIVITY SENSORS Sea-Bird conductivity sensors provide
DISCUSSION OF PRESSURE CORRECTION Conductivity cells do not measure the specific conductance (the desired property), but rather the conductance of a
APPLICATION NOTE NO. 14 January 1989 1978 PRACTICAL SALINITY SCALE Should you not be already familiar with it, we would like to call yo
Instrument Configuration: Serial Number 37SI64195-8524 Pressure Sensor None Firmware Version 3.0j Memory 8192Kb Interface Type RS-232
1 APPLICATION NOTE NO. 31 Revised February 2010 Computing Temperature and Conductivity Slope and Offset Correction Coefficients from Laboratory
2 To correct conductivity data taken between pre- and post-cruise calibrations: islope = 1.0 + (b / n) [(1 / postslope) - 1.0] where islope = int
3 Example Three salinity bottles are taken during a CTD profile; assume for this discussion that shipboard analysis of the bottle salinities is perfec
4 Temperature Sensors The temperature sensor slope and offset entries in the configuration (.con or .xmlcon) file in SEASOFT permit the user to make
5 Correcting for Temperature Drift Based on Pre- and Post-Cruise Laboratory Calibrations Suppose a temperature sensor is calibrated (pre-cruise), the
6 Appendix I: Example Conductivity Calibration Sheet 83
7 Appendix II: Example Temperature Calibration Sheet 84
1 APPLICATION NOTE NO. 42 Revised February 2010 ITS-90 TEMPERATURE SCALE Beginning in January 1995, Sea-Bird's temperature metrology laborat
1 APPLICATION NOTE NO. 68 Revised June 2009 Using USB Ports to Communicate with Sea-Bird Instruments Most Sea-Bird instruments use the RS-232
SBE 45 MicroTSG (Thermosalinograph) Conductivity and Temperature Monitor with RS-232 Interface Note: NEW ADDRESS as
1 APPLICATION NOTE NO. 71 Revised March 2008 Desiccant Use and Regeneration (drying) This application note applies to all Sea-Bird instruments in
2 Regeneration (drying) of Desiccant Replacement desiccant bags are available from Sea-Bird: • PN 60039 is a metal can containing 25 1-gram desiccan
ISO 9002 CERTIFIED Sud-Chemie Performance Packaging 101 Christine Dr. Belen, New Mexico 87002 Phone: (505) 864-6691 Fax: (505) 864
ISO 9002 CERTIFIED Sud-Chemie Performance Packaging 101 Christine Dr. Belen, New Mexico 87002 Phone: (505) 864-6691 Fax: (505) 864
ISO 9002 CERTIFIED Sud-Chemie Performance Packaging 101 Christine Dr. Belen, New Mexico 87002 Phone: (505) 864-6691 Fax: (505) 864
ISO 9002 CERTIFIED Sud-Chemie Performance Packaging 101 Christine Dr. Belen, New Mexico 87002 Phone: (505) 864-6691 Fax: (505) 864
DRAWINGSDwg 50179SBE 45 External I/O Wiring, RS-232...
95
Kommentare zu diesen Handbüchern